Description
The 3M A125 Noise Reduction board (3M part number 78-9236-6453-2) improves the inbound intelligibility of an
intercom system by reducing environmental background noise from vehicles, airplanes, noisy intersections, wind,
etc.
System Requirements
The 3M A125 Noise Reduction Module requires a 3M model C921BA or C922AA Base Station.
Installing the Noise Reduction board into the 3M Base Station
1. Remove the right-hand and left-hand top covers from the 3M base station. Be careful that the main circuit
board does not fall out of the plastic base.
2. See ***Important installation notice*** on next page before performing this step.
Plug the A125 ribbon cable onto connector J8, located at the top of the left side of the circuit board. Be careful
to support the rear side of the base station circuit board when plugging in the A125 ribbon cable.
3. Position the holes near the edge of the A125 circuit board over the plastic standoffs on the base station.
4. Attach the left-hand base station cover after configuring the A125 board, and performing the Final Checkout
Procedure.
Install the A125 board here
Figure 1. Mounting the A125 to the C921BA Base Station
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Installation Instructions

Noise Reduction Module Model A125 Installation Instructions Description The 3M A125 Noise Reduction board (3M part number 78-9236-6453-2) impro

Page 2

2***Important installation notice*** Starting with serial number 125002477, the A125 Noise Reduction Module, Internal has a wider ribbon cable plug.

Page 3 - Mode Configuration

3 System Configuration The A125 Noise Reduction board is configured by two jumper switches, (JMP1 and JMP2), shown in Table 1. Jumper Position Posi

Page 4 - Troubleshooting

4Status Indication The condition of the red LED on the 3M C960 base station indicates the current status of the unit. The LED can be off, blink at