3M C3266PW User's Guide Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
46 3M™ Multi-Touch Chassis Display User Guide
3M Touch Systems, Inc. Proprietary Information – TSD-39373B
Get Copyright
Syntax: <SOH>Q101<CR>
Response: <SOH>Copyright © 2011 3M. All rights reserved.<CR>
Description: This command is used to get copyright information.
Mode Down Up
Syntax: <SOH>MDU<CR>
Response: <SOH>0<CR> Positive response.
Description: Limits touch reports to touchdown and liftoff events only.
Mode Inactive
Syntax: <SOH>MI<CR>
Response: <SOH>0<CR> Positive response.
Description: Turns off touch reports
.
Mode Stream
Syntax: <SOH>MS<CR>
Response: <SOH>0<CR> Positive response.
The controller will respond with acknowledge (ACK) for compatibility. This format is
the only format supported by this controller.
Description:
This is the default mode of operation at power up. Touch reports include
touchdown and liftoff events as well as continuing touches.
Name Command
Syntax: <SOH>NM<CR>
Response: <SOH>0<CR> Positive response.
Description: Returns a name string
Null Command
Syntax: <SOH>Z<CR>
Response: <SOH>0<CR> Positive response.
Description: Queries the controller and waits for a response.
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 52 53 54

Comments to this Manuals

No comments